Published · 2026-10-13 Sandwich panel fire documents: match the report to the proposed supply Before comparing offers, put the requested panel and the report reference in the same enquiry. A brochure headline is not enough to show which configuration the document covers. Core classification, finished-panel reaction to fire and assembly fire resistance are different evidence scopes. [2] The tested configuration and report application limits matter. [1] Ask the supplier to identify the document for the offered configuration. Record mismatches and missing documents as open questions. Send those questions to the project reviewer before confirming the order. This checklist records purchasing information; it does not approve the design or state that ZY holds a particular classification. Fictional comparison: offer A names a core material; offer B gives a finished-panel report reference. These are different document descriptions. Request the covered product and configuration for both, rather than choosing a winner from the headings. 1. Project location and intended panel use: ____________________ 2. Project reviewer and required evidence: ____________________ 3. Offered manufacturer and product identifier: ____________________ 4. Core, facings, panel thickness and joint drawing: ____________________ 5. Claimed performance and applicable standard/version: ____________________ 6. Report number, issuer and issue date: ____________________ 7. Report product/configuration and application limits: ____________________ 8. Installation drawing and proposed variations: ____________________ 9. Missing documents or unresolved mismatches: ____________________ 10. Reviewer response and order-document revision: ____________________ Attach the relevant report and panel drawing, or mark them To confirm. Please do not replace missing evidence with a stock photograph or a supplier catalogue rating. [1] Approved Document B: Fire safety - frequently asked questions https://www.gov.uk/guidance/approved-document-b-fire-safety-frequently-asked-questions [2] Spanrock stone wool for sandwich panels https://coresolutions.rockwool.com/en/solutions-and-applications/stone-wool-for-sandwich-panels/insulation-core-for-sandwich-panels/ Turn a discrepancy into a supplier question For each report reference, write the offered detail beside the covered detail. If the product identifier, panel thickness, facing, joint or installation is missing or different, identify the exact field and ask for clarification. Record the supplier’s answer and the reviewer’s response with the same drawing revision. “Document received” and “review completed” are separate statuses; an unanswered row remains open. This is a document-control exercise, not a judgement that either panel passes or fails. Sources checked on 13 October 2026. Source [1] applies to England and explains reaction-to-fire application limits; it is not a global project rule. Source [2] describes one manufacturer’s core and finished-panel evidence scopes. No manufacturer classification, certification or performance is assigned to ZY.