CLEANROOM PARTITION ENQUIRY WORKSHEET Product: Specialist Cleanroom Partition Systems 1. Company / contact / email / project reference: 2. Destination country and city / wall area or quantities / requested programme: 3. Selected configuration: removable panels / return-air modules / thermal break / service openings / corners / bases or profiles / facing requirements / to confirm: 4. Room plan and wall elevations / drawing revision / dimensions and measurement units: 5. Wall heights / module widths / panel thickness / cut lengths and panel quantities: 6. Panel core and complete layer build-up / facing material, grade and finish on each side: 7. Support and fixing arrangement / interfaces to structure / openings and equipment loads / responsible structural designer: 8. Cleaning agents, concentration, contact time and frequency / temperature and humidity / required compatibility evidence: 9. If VHP exposure is required: specified process conditions and cycles / facing, joints, seals and adhesives included in compatibility review: 10. Return-air module locations / duct and grille interfaces / airflow and pressure requirements from the HVAC designer / maintenance access: 11. Removable panel locations / equipment movement dimensions / removal direction and sequence / access clearance / resealing and acceptance responsibility: 12. Door and observation-window opening schedule / opening and frame dimensions / wall thickness / included hardware or glazing scope: 13. Service penetrations and factory-prepared openings / drawing dimensions and revisions / site modifications and resealing responsibilities: 14. Wall-base, floor, ceiling and corner junction drawings / coving, U channels, profiles and seals / room and adjacent thermal conditions: 15. Required assembly drawings and applicable reports / fire or pressure requirements if specified / criteria, test conditions and acceptance responsibility: 16. Supply-only or coordinated package / included components and installation / packing, spares and requested delivery schedule: Unknown details: To confirm Record the wall layout, layers, supports, openings, cleaning conditions and supply scope. Confirm compatibility for the specified facing, joints, seals and VHP exposure conditions where required. A panel or catalogue photograph does not establish completed room classification, leakage performance or a validated decontamination process. Agree design and acceptance responsibilities in the quotation. Edited requirements are kept when changing language.