ZY CLEANROOM - PU / PHENOLIC PANEL ENQUIRY WORKSHEET English edition prepared 6 October 2026. Complete one schedule for each distinct panel construction. 1. Project reference, destination country / city and delivery location: 2. Contact name, company and email: 3. Intended use: partition wall / ceiling / temperature-controlled enclosure / other; drawing reference and revision: 4. Required core: PU / phenolic / other / To confirm; state whether "phenolic" refers to the core, facing or both: 5. Complete layer construction, requested formulation / density information and offered model code (to confirm): 6. Overall panel thickness; catalogue width series; overall width; effective cover width; drawing units and tolerances (separate values): 7. First metal face: material / grade, BMT or TCT basis where applicable, thickness, coating / finish and colour: 8. Second metal face: material / grade, BMT or TCT basis where applicable, thickness, coating / finish and colour: 9. Panel marks, cut lengths and quantity for each length; state units and any area calculation basis: 10. Joint profile, seals, trims, fixings, support arrangement and installation details: 11. Door, window and service openings; ceiling loads and accessory requirements for designer review: 12. Room conditions, cleaning agents / method and maintenance requirements: 13. Required thermal / fire / other documents: applicable test method, tested assembly, intended use and destination requirements: 14. Design, supply, installation and acceptance responsibilities; list included and excluded accessories: 15. Packing, transport / site access constraints, requested delivery programme and delivery terms: Attach the section drawing, layout and panel schedule with the same project reference. Mark unknown details "To confirm" and state units for all dimensions. PU catalogue references do not establish phenolic or PIR availability, dimensions or performance. Ask for confirmation of the actual offered construction and applicable documents. Keep each face-sheet thickness separate from the overall panel thickness. Identify the thickness basis rather than comparing unspecified thickness values. A core name, photograph or catalogue dimension does not establish a fire rating, allowable ceiling load or an ISO cleanliness class for a room. Requested specifications and dates are inputs for quotation review. This worksheet is not an approved design, a performance certificate, a stock statement or a delivery commitment. The agreed quotation and drawings define the offered configuration and supply scope. Send drawings and the completed worksheet to info@zycleanroom.com using the same project reference.