What information is needed to quote cleanroom panels?
Start with the wall and ceiling drawings, panel core, finished thickness, facing material, dimensions, quantities and delivery location. Add the project fire requirements, cleaning process and any structural or installation constraints. If a detail is undecided, identify it as an open item so suppliers can quote comparable alternatives.
ZY Cleanroom supplies cleanroom sandwich panels and associated doors and access components. Send a specification or drawing to info@zycleanroom.com for a project review.
Cleanroom wall panels and ceiling panels: what should buyers compare?
A wall panel quotation and a ceiling panel quotation should identify their intended installation separately. Ask the supplier to document the proposed support arrangement, panel connections and loading assumptions. Do not assume a ceiling is walkable because its panel thickness matches a wall panel.
| Specification item | Information to provide or request |
|---|---|
| Wall layout | Room dimensions, panel heights, corners, junctions and door/window openings. |
| Ceiling layout | Grid or suspension design, spans, service openings and intended access requirements. |
| Core and facing | Material type, steel or other facing specification, coating, colour and finish. |
| Joints and accessories | Connection profiles, edge details, sealants, coving and interfaces with adjacent systems. |
| Performance evidence | Reports that match the offered panel assembly and the project acceptance criteria. |
| Delivery | Destination, preferred trade terms, packing, unloading and installation responsibilities. |
Include channels, coving, frame profiles and ceiling connections in the panel schedule. Review catalogue accessory families and the drawings needed for a coordinated quotation.
For handmade panels, the ZY company catalogue illustrates a center aluminum connection and a male–female connection. Compare the original handmade panel joint diagrams, then request the proposed profile dimensions and sealing details for your quotation.
Do you need sandwich ceiling panels or lay-in ceiling tiles?
Identify the ceiling system before comparing products called “cleanroom ceiling panels.” A sandwich-panel quotation needs the panel construction, connection detail and proposed support arrangement. A lay-in panel quotation needs the specified ceiling grid and compatible panel size, edge and sealing details. The product name alone does not show whether two offers cover the same installation.
For a market example, Gold Bond lists Gridstone CleanRoom panels within gypsum lay-in panel systems and describes a vinyl-laminated gypsum core with sealed exposed edges. See the manufacturer's Gridstone CleanRoom construction description. This is a terminology example, not a ZY product or a performance claim for ZY panels.
Include in your ceiling RFQ: the ceiling-system drawing, panel schedule, grid or suspension layout, service openings, edge and seal requirements, and intended maintenance access. If access above the ceiling is required, request the proposed access arrangement and its applicable load assessment separately.
Compare the ZY handmade panel connections illustrated in the company catalogue with your intended system, and ask for the offered ceiling assembly drawing before approving the order.
How do you compare rock wool, PU, phenolic and honeycomb panels?
Compare documented performance for the actual offered construction. Review thermal performance, weight, facing, moisture suitability, support requirements and applicable fire evidence. The core name alone is insufficient to approve the complete panel assembly.
Use our panel core material guide to organise questions, then compare PU and phenolic panels and honeycomb panels against the same project specification. Confirm whether any proposed alternative changes panel connections, openings or supporting components.
Handmade, Rock Wool TG or PU: Which Panel Size Applies?
Start with the complete panel family and joint profile. A rock wool core can appear in different constructions; it does not determine one universal panel width. The company catalogue separates these references:
- Handmade panel family — printed pages 15–16
- Standard width 1,180 mm and thickness 50 mm; listed length 100–6,000 mm with project adjustment described. Confirm the selected core and center-connector or male–female connection. See handmade joint examples.
- Rock wool tongue-and-groove series — printed pages 13–14
- The catalogue labels 950 mm and 1,150 mm width series, with HA-RW-TG950 and HA-RW-TG1150 model references. Specify the full model code and request its dimensioned section; confirm whether the width in the quotation means overall width or effective coverage. See the catalogue family reference.
- PU tongue-and-groove models — printed pages 21–22
- Catalogue widths of 950 mm or 1,150 mm and thicknesses of 40, 50, 75, 100, 150, 200 or 250 mm. These are PU references; they do not establish phenolic or PIR dimensions. See PU quotation checks.
Before comparing a price per m²: agree the panel family, effective coverage width, thickness, cut lengths, joint and included accessories. A quotation for a 1,180 mm handmade panel cannot automatically replace a 950 mm tongue-and-groove layout.
For roof or ceiling applications: send the support layout and design requirements. A catalogue width or core description does not establish a safe span, load capacity or fire rating. Request the applicable documents for the exact assembly.
Phenolic core or phenolic facing: which panel do you need?
Specify the core and the outer faces separately. A request for a phenolic core identifies the panel's middle layer; a request for phenolic facing identifies an outer surface. These descriptions do not define the same construction.
For example, Modular Clean Panel lists a panel with phenolic resin exterior faces and a rock wool core. See the manufacturer's MCP-RES-LR construction description. This illustrates terminology, not an offered ZY model or evidence for its performance.
- Identify each layer: write the required core, face-sheet material and finish in separate RFQ fields.
- Define dimensions: state the overall panel thickness and any required face-sheet thickness, then request the proposed section and joint drawing.
- Match the evidence: compare reports for the complete offered assembly and the specified use, rather than transferring another core or facing's results.
Check current availability and model details through our PU and phenolic panel enquiry options. Mark an undecided core or facing as an open item in your request.
Does a cleanroom panel have an ISO cleanliness class?
ISO 14644-1 classifies air cleanliness by particle concentration in cleanrooms and clean zones. It does not assign a room's air cleanliness class merely from the chosen wall-panel core. A panel purchase should be coordinated with the room design, air system, installation and agreed testing scope.
Reference: ISO 14644-1:2015, official scope and standard information. Consult the applicable standard and project specialists for the required assessment.
What affects the price of cleanroom sandwich panels?
A comparable cleanroom panel price per m² needs an agreed panel construction, quantity and supply scope. Use the same wall and ceiling schedules when requesting offers, and compare the complete quoted scope before comparing unit prices.
What should a cleanroom panel quotation include?
- 1. Panels and fabrication
- Identify the core, overall thickness, face-sheet material and thickness, coating, joints and drawing revision. List dimensions and quantities, with cut-outs and special fabrication stated separately.
- 2. Profiles and accessories
- List connections, perimeter trims, coving, sealants and fixings. Identify door, window and equipment interfaces, and mark components supplied by others.
- 3. Packing
- State the protective packing, package dimensions and weights. Confirm handling requirements and whether packing is included in the panel price or charged separately.
- 4. Transport and delivery
- State the delivery location, agreed trade term and edition, and included transport charges. Identify unloading and clearance responsibilities and charges outside the supplier's offer.
- 5. Services and documentation
- Separate installation, supervision, drawing work and any agreed testing or inspection services. List the product documents to be supplied and the services excluded.
How is the quoted area measured?
Confirm whether square metres are calculated from ordered panel dimensions or effective coverage, and how openings, cut-outs and offcuts are billed. Keep wall and ceiling quantities separate. A room's floor area alone does not define the area of panels to order.
How do you compare two export quotations?
Match the specification, quantity basis, currency, quotation validity and delivery location. Record every inclusion, exclusion and unresolved item. If a charge is included in one offer but excluded from the other, obtain the missing amount before comparing totals; avoid adding freight twice when it is already included.
ICC explains that Incoterms® rules allocate delivery tasks, costs and risks between seller and buyer. See the International Chamber of Commerce's official Incoterms® information when agreeing the delivery scope.
Request a Panel Price Quotation
Before approving production
- Confirm the specification, drawings and revision numbers.
- Confirm dimensions, quantities and the treatment of openings and joints.
- Review the documents required for acceptance and match them to the offered product.
- Agree packaging, delivery responsibilities and installation interfaces.
- Resolve open items in writing before production approval.
Send Your Panel Requirements Planning a complete room? Use the project RFQ checklist.