Which cleanroom panel sizes are listed in your catalogue?
The company catalogue lists hand-made panels with a standard thickness of 50mm, width of 1,180mm and cut lengths of 100–6,000mm (printed pages 15–16). PU tongue-and-groove models list widths of 950mm and 1,150mm and thicknesses of 40, 50, 75, 100, 150, 200 and 250mm (pages 21–22). These are different product families; confirm the current offered model in the quotation. See hand-made panels and PU panel options.
How should I compare hand-made and machine-made panels?
Compare the offered panel assembly, core, metal faces, edge reinforcement, joint profile and dimensions. The catalogue shows framed hand-made panels and tongue-and-groove models. Give us your wall and ceiling schedules so the quotation can identify the selected construction and accessories. Production method alone does not establish fire performance or allowable loads.
Can wall panels also be used as ceiling panels?
Request a separate ceiling assembly assessment. Provide support spacing, penetrations, equipment interfaces and maintenance access requirements. Confirm the allowable loads for the selected assembly; thickness alone is not a load rating. Include separate wall and ceiling areas in your panel schedule.
How do I confirm a panel fire rating?
Request the current test report for the exact assembly, including core, faces, thickness and joints. Check the test standard, tested configuration and applicability to the destination requirements. A core material name or a brochure rating should not be treated as proof that every panel configuration has that rating.

Room Classification & Equipment

Does a sandwich panel determine the cleanroom ISO class?
No. ISO 14644-1 classifies air cleanliness by airborne particle concentration. Specify the required room classification, occupancy state and acceptance testing with your project team. Panel materials and sealed joints form part of the enclosure; they do not independently prove that a complete room meets an ISO class. ISO 14644-1 scope.
Is an ISO cleanroom class the same as GMP compliance?
They address different requirements. A room particle classification does not, by itself, establish GMP compliance. Provide the process requirements, applicable project standards and intended acceptance documents when requesting an engineering quotation.
Does H13 or H14 filter classification guarantee a room ISO class?
No. Specify the filter classification and the room acceptance requirements separately. Request the factory report identifying the offered filter and its test conditions; agree installed-filter and housing verification separately from completed-room acceptance. Include the frame size, sealing interface, airflow and pressure-drop requirements in your RFQ. See the HEPA and ULPA selection comparison.
What information is needed to quote an FFU or HEPA terminal housing?
Include the equipment schedule, external dimensions, ceiling or duct interface, required airflow, filter classification, power and control requirements, quantity and destination. Identify the tests and reports required for the offered assembly. Confirm access for installation, filter replacement and maintenance in the drawing review. Compare FFUs and air equipment before requesting a quotation.
How do I choose between static, dynamic and VHP pass boxes?
Start with the transfer procedure, largest packaged load, usable chamber and opening dimensions, wall interface and door sequence. For dynamic options, confirm the offered filtration, airflow and testing arrangement. For VHP options, define load compatibility, cycle development, validation and release responsibilities. A product name alone does not prove sterile transfer. Review the pass box types and RFQ checklist.
Is the clear door opening the same as the construction opening?
No. The clear passage, construction opening, frame dimensions and door leaf dimensions describe different measurements. Provide the required usable passage, wall thickness, finished floor level and handing; approve the model-specific drawing before preparing the opening. Use the cleanroom door size guide and confirm observation-window panel interfaces separately.

Building materials

What should I send for a steel floor decking quotation?

Send the floor layout, profile drawing, sheet marks, cut lengths and quantities. Specify the steel grade, thickness basis, coating, supports, openings and required accessories. Separate construction-stage and completed-floor requirements, and identify any temporary propping in the design. Floor area alone does not define the sheets or establish load capacity. Mark unresolved details “To confirm”.

Floor decking details · Quotation worksheets

What information is needed to quote C and Z purlins?

Include the section drawing, steel grade, thickness basis, coating and a schedule of member marks, cut lengths and quantities. Show hole sizes, slots, positions and their measurement datum. Identify the connections, laps, bridging and restraints required by the designer, and list included accessories separately. C and Z sections are not interchangeable solely because their nominal depth and thickness match.

C/Z purlin details · Quotation worksheets

How do I prepare a roof or wall sheet enquiry?

Send the roof layout or wall elevations, profile drawing, effective cover width, material, thickness basis, coating or finish, colour, sheet lengths and quantities. Show supports, fixing arrangements, openings and junction details; include roof slope for roofing. State the destination and the requested supply scope. Use the relevant quotation worksheet and mark missing requirements “To confirm”; the worksheet does not approve a design or certify performance.

Roof sheet details · Wall sheet details · Quotation worksheets

Quotation & Delivery

What information is needed for a cleanroom panel price quotation?
Send the destination country, wall and ceiling areas, dimensions, core and face requirements, openings, joints, trims, required documents and delivery terms. Ask the quotation to separate panels, accessories, packing, transport and installation. Use the panel quotation comparison checklist to compare supply scopes.
What is the minimum order quantity and can I request samples?
Ask for the MOQ and sample arrangements for your selected model and destination. Confirm any sample charges, courier costs and whether a sample credit applies to a later order in writing. Sample conditions and minimum quantities should be stated in the quotation.
How do I confirm production and delivery lead times?
Provide the quantity, approved panel schedule, selected materials and destination. Request separate estimates for drawing approval, production, packing and transport, and confirm what triggers each stage. Use the quoted schedule for planning rather than a general website estimate.
What should an overseas delivery quotation include?
State the delivery destination and preferred delivery terms. Ask for the packing method, package dimensions and weight, transport scope and available export documents. Identify who handles freight, customs and local delivery in the agreed supply scope. Use the panel export packing and delivery checklist; if the package includes wood, confirm the wood-packaging requirements.
Can installation or local contractor support be included?
Yes. On a turnkey contract ZY installs, with a licensed local contractor named in the contract where your country requires licensed works. On supply-only orders ZY supports your crew with numbered panel drawings, an installation guide, remote video support for set-out and the first panels, and on-site supervision for larger projects; installer training can be included. Give the country, site conditions and schedule in the RFQ, and the installation scope is written into the quotation.
Which documents and payment terms should I confirm before ordering?
Request the current company certificates, model-specific material and assembly reports, inspection criteria and any project acceptance records required by your specification. Confirm document availability, payment stages and supply responsibilities in the quotation and sales agreement. For an inquiry, email info@zycleanroom.com or use the contact form.

Prepare a cleanroom project RFQ · Discuss your project

Classification references

ISO 14644-1: particle concentration classificationEU GMP Annex 1: manufacture of sterile medicinal products
WhatsApp
⚡ Quick Quote