PU Cleanroom Panels: Sandwich Panels for Cleanrooms and Insulated Rooms
PU panels are tongue-and-groove sandwich panels with a polyurethane foam core between metal faces. Buyers use them for partitions, cleanroom walls and ceilings, and insulated enclosures. They are made in our own factory in Binhai New Area, Tianjin, on the same site as our rock wool and handmade cleanroom panels. PU panels are our insulation-led panel. Use them for cleanroom walls and ceilings where the room is held at a different temperature from the space around it, such as cold rooms, chilled process rooms and temperature-controlled stores, and where your fire rules allow a foam core. Where a non-combustible core is required, compare rock wool in the same width series.
Best for
- Partition walls
- Cleanroom walls and ceilings
- Insulated enclosures
- Temperature-controlled rooms
Specifications
Typical specification
| Core | Polyurethane (PU) foam |
|---|---|
| Width series | 950 mm or 1,150 mm (effective cover width is confirmed in the quotation) |
| Listed thicknesses | 40, 50, 75, 100, 150, 200 and 250 mm |
| Metal faces | Colour-coated, galvanized or embossed steel |
| Joint | Male-female tongue-and-groove |
| Length | Set by your panel schedule; manufacturing and transport limits are confirmed in the quotation |
| PIR and phenolic | Availability confirmed on request. PU sizes do not apply to them |
| Thermal and fire documents | Requested per model and tested assembly |
| Model codes | HA-PU-TG950/40 to /250 and HA-PU-TG1150/40 to /250 (14 codes, see table below) |
Options
What you can specify
- 950 or 1,150 mm width series
- Seven listed thicknesses from 40 to 250 mm
- Colour-coated, galvanized or embossed steel faces
- PIR or phenolic core, availability confirmed on request
- Cut lengths to your panel schedule
How to choose a PU panel
PU panels are lighter than rock wool and are usually chosen for insulation, for example in cold rooms. Where a non-combustible core is required, compare rock wool cleanroom panels in the same width series.
PU, PIR and phenolic are different cores. State which one you need, and whether phenolic refers to the core or to the facing. Thermal and fire performance belong to the tested assembly, so ask for model-specific documents.
For the whole wall system, see cleanroom wall panels and all cleanroom sandwich panels.
Where PU cleanroom panels are used
PU is the core we propose when insulation is the main job of the wall and your fire rules allow a foam core. Typical uses:
| Application | Why PU | What to check |
|---|---|---|
| Cold rooms and chilled process rooms | Insulation is the main need, and the panel is lighter than rock wool | Temperature and humidity on both sides of each wall; who designs condensation control |
| Temperature-controlled stores and insulated enclosures | Seven listed thicknesses from 40 to 250 mm, chosen for the insulation you need | The declared thermal value for the exact thickness |
| Cleanroom walls and ceilings in air-conditioned rooms | Smooth steel faces and tongue-and-groove joints in the 950 or 1,150 mm series | Face finish, joint sealing and the cleaning agents used in the room |
| Cold cleanrooms | One wall can meet both the cold room and the cleanroom requirements | Flush door and window frames, sealed joints and sealed penetrations |
| Partition walls | A light panel for internal partitions | The fire report for the exact panel if the partition separates fire zones |
Where a non-combustible core is required, such as a fire-separating wall, start from rock wool cleanroom panels or hollow MgO panels.
Model codes
The catalogue lists one code per width and thickness. Put the code on your enquiry and ask for the section drawing.
| Thickness | 950 mm series | 1,150 mm series |
|---|---|---|
| 40 mm | HA-PU-TG950/40 | HA-PU-TG1150/40 |
| 50 mm | HA-PU-TG950/50 | HA-PU-TG1150/50 |
| 75 mm | HA-PU-TG950/75 | HA-PU-TG1150/75 |
| 100 mm | HA-PU-TG950/100 | HA-PU-TG1150/100 |
| 150 mm | HA-PU-TG950/150 | HA-PU-TG1150/150 |
| 200 mm | HA-PU-TG950/200 | HA-PU-TG1150/200 |
| 250 mm | HA-PU-TG950/250 | HA-PU-TG1150/250 |
A width series name is not the effective cover width. Confirm the cover width on the section drawing before you count panels.
Which thickness?
No cleanroom standard fixes a panel thickness. Thickness follows the job the wall has to do:
- Insulation. A room held well below or above the temperature of the space around it needs more insulation. Ask for the declared thermal value for the exact thickness, and compare suppliers on the same basis. Our thermal value comparison sheet shows how.
- Span. Taller walls and longer ceiling spans need a stiffer panel. Ask for an assembly-specific span or load check; thickness alone does not set a ceiling load.
- Frames and openings. Our door frames and observation windows are listed for 50, 75 and 100 mm walls. If you choose another thickness, ask how doors and windows will be fitted.
PU panels for temperature-controlled cleanrooms and cold rooms
A room held below the temperature of the space around it has two jobs: keep the heat out and keep moisture from condensing in the wrong place. The panel is only part of the answer. Send these with the enquiry:
| Send | Why |
|---|---|
| Room temperature and relative humidity inside | Sets the insulation and the condensation check |
| Temperature and relative humidity on the other side of each wall and the ceiling | Each side of a wall can see different conditions |
| Floor build-up | An insulated room loses heat through an uninsulated floor |
| Ceiling: hung or self-supporting, and the void conditions above | A low-temperature ceiling may need a thermal-break design |
| Doors, windows and pass boxes in the cold walls | Every opening is a thermal and air-leak path |
| Penetrations for pipes, refrigerant lines and cables | Each one must be sealed |
Our cleanroom ceiling range includes low-temperature thermal-break ceilings. Agree in the quotation who is responsible for the condensation-control design. A panel described as insulated does not by itself make an assembly condensation-free.
Cold room panel thickness by temperature difference
One design check used for cold stores limits the heat conducted through the walls to about 10 W/m². Dividing that limit by the panel's U-value gives the largest temperature difference a panel can hold. The table uses a core-only U-value from λ = 0.022 W/(m·K), the most common published PIR figure, so it errs on the thick side.
| Panel thickness | Core-only U-value, W/(m²·K) | Largest temperature difference at 10 W/m² | Example that fits |
|---|---|---|---|
| 75 mm | 0.29 | About 34 °C | Chilled room at +2 °C, +30 °C outside |
| 100 mm | 0.22 | About 45 °C | Chilled room at +2 °C, +45 °C outside |
| 150 mm | 0.15 | About 68 °C | Freezer at −20 °C, +45 °C outside |
| 200 mm | 0.11 | About 91 °C | Blast freezer at −35 °C, +45 °C outside |
This is for early sizing only. The refrigeration designer's heat-load calculation sets the final thickness, and the floor, doors and ceiling need their own check.
Comparing insulation between quotes
Ask every supplier for the declared thermal conductivity (λ, in W/m·K) or the declared U-value of the exact panel and thickness, measured on the same basis. Then compare like with like.
Worked example, assumed values: a core with λ = 0.022 W/m·K, 100 mm thick, has a core-only U of about 0.022 ÷ 0.100 = 0.22 W/m²·K. At 50 mm it is about 0.44 W/m²·K. The faces, joints and surface resistances change the final figure, so use the declared value for the panel, not this arithmetic, in your design. The 0.022 is an assumption for the example, not a declared value for our panels.
Industry reference values for PU and PIR panels
The main European panel makers publish these figures for panels with a polyurethane-family core, mostly PIR. They are industry reference values, not test results for our panels. Use them to check that a quotation is in a sensible range, and design with the value declared for the panel you buy.
| Property | Industry reference range | How to read it |
|---|---|---|
| Thermal conductivity λ of the core | 0.018–0.022 W/(m·K), declared aged value | Most published PIR figures are 0.022; values near 0.018 come from proprietary core formulations |
| U-value, 50 mm panel | 0.38–0.51 W/(m²·K) | Calculated by the EN 14509 method, which includes the joints |
| U-value, 75 mm panel | Not published; core-only estimate 0.24–0.29 W/(m²·K) | Our own arithmetic, λ divided by thickness |
| U-value, 100 mm panel | 0.18–0.22 W/(m²·K) | EN 14509 method |
| U-value, 150 mm panel | 0.12–0.15 W/(m²·K) | EN 14509 method |
| Core density | 38–40 kg/m³ | Published by several makers |
| Reaction to fire, EN 13501-1 | PIR panels are commonly classed B-s1,d0 or B-s2,d0; some products are classed lower | A class belongs to one tested product, face and thickness. The class of our PU panels waits for the factory test report |
PU or rock wool?
| PU panel | Rock wool panel | |
|---|---|---|
| Core | Organic foam | Non-combustible mineral wool |
| Weight | Lighter | Heavier |
| Usually chosen for | Insulation, cold rooms, insulated enclosures | Fire-separating walls, rooms where a foam core is not allowed |
| Widths | 950 or 1,150 mm series | 950 or 1,150 mm series; handmade 1,180 mm |
| Thicknesses | 40–250 mm | 40–250 mm (tongue-and-groove); 50 mm standard handmade |
| Fire class | Depends on formulation; ask for the report | Ask for the report on the exact build |
If your fire rules or insurer do not allow a foam core, start from rock wool panels. For a full comparison, see the panel selection guide.
How PU compares with the other cores we make
| Core | Fire note | Weight | Insulation | Use it when |
|---|---|---|---|---|
| Rock wool | Non-combustible mineral core | Heaviest of the mineral cores | Better than hollow MgO | A combustible core is not allowed and insulation matters |
| Hollow MgO | Non-combustible inorganic core | Medium | Moderate | You want a lighter non-combustible panel in a dry room |
| PU | Organic foam; class depends on formulation and test | Light | Used for insulation-led rooms | Insulation is the main need and fire rules allow foam |
| Honeycomb (aluminium or paper) | Depends on the core | Light | Confirmed on the quotation | Light partitions and ceilings with a support design |
Fire rules set the shortlist. A core name does not give a fire rating. The rating belongs to the tested panel, so ask for the report that covers the faces, core and thickness on your quotation. For the Euroclass system, see our panel selection guide.
In short: PU leads on insulation and light weight; rock wool and hollow MgO are the non-combustible cores; honeycomb is light for walls and ceilings in dry rooms.
Installation notes for PU panels
The panels go up in the usual order for a panel cleanroom: floor and base track, wall panels, corners, ceiling, doors and windows, then lights, filters and penetrations, and a final seal and leak test. Each step and its check are in our cleanroom panel installation guide. The points that matter most for this core:
- Set out from the cover width. Count panels with the effective cover width on the section drawing, not the 950 or 1,150 mm series name.
- Leave room for tolerance. EN 14509 allows ±2 mm on the useful width, so ten panels can add up to 20 mm along a wall. Decide before set-out where the closing panel is cut.
- Seal every opening in a cold wall. Doors, windows, pass boxes, pipes, refrigerant lines and cables are thermal and air-leak paths, so seal each one as it is installed.
- Build the floor and ceiling as drawn. An insulated room loses heat through an uninsulated floor, and a low-temperature ceiling may need a thermal-break design.
- Seal the room side. Joints are sealed on the room side with a sealant that tolerates the cleaning agents used in the room.
On turnkey contracts our own crew installs the panels, doors and ceilings. On supply-only orders your crew installs them with our numbered layout drawing and installation guide, and our engineer can join a WhatsApp video call to check set-out and the first panels.
Installation and what ships with the order
Each order can ship with numbered panels cut to length, a layout drawing, an installation guide in English, Spanish, Portuguese, Arabic or Russian, an accessory kit (floor tracks, aluminium profiles, corner coves, flashings, screws and sealant) and a WhatsApp video call with our engineer for set-out and the first panels. Panels are packed strapped and stacked on timber pallets. See installation support.
What goes wrong on site
A width series is not an effective cover width, so confirm it before you calculate quantities. Ceiling loads and accessories need a separate assessment. A panel does not set a room's ISO class by itself.
Test results for one core do not carry over to another. Do not apply PU data to a PIR or phenolic panel.
Packing and shipping to your site
Panels and doors are manufactured in our Tianjin factory, cut to length, numbered to the layout drawing and packed on timber pallets. The packing list follows the panel numbering, so each pallet can be matched to a zone of the layout on arrival. Other equipment is inspected before shipping, and your inspection company can check the goods before loading.
State the freight term and the port or site city in the quotation, and ask your broker to confirm the customs code before shipment. See how to import a cleanroom from China.
How to ask for a quotation: what to send
Send the destination country and a panel schedule with cut lengths. Give the required core, both metal faces, the effective cover width and the joint details. For cleanroom use, add the face finish, joint sealing, the cleaning agents used and your acceptance requirements. List trims, sealants, packing and any installation work you want in the scope.
Build the room list in our room list builder: area, target class or condition and pressure for each room. Send it with the items above on WhatsApp (+44 7962 561184) or through the form below. We reply with a scope list and a first budget range; the price is confirmed in a written quotation.
Quote checklist
| Send | Why |
|---|---|
| Model code or width series and thickness | One code per width and thickness |
| Panel schedule with cut lengths and quantities | Panels are cut and numbered to the layout |
| Room temperatures, inside and outside | To check the thickness against the insulation you need |
| Both faces: steel type, coating, colour | Colour-coated, galvanized or embossed |
| Core: PU, PIR or phenolic | Different cores; test data does not carry over |
| Trims, sealants, floor and ceiling details | Listed in the scope so quotations compare line by line |
| Reports you need | Fire or thermal reports, for the exact build |
| Destination country and port | Packing and freight |
Cleanroom panel selection: core materials compared
How to Choose a Cleanroom Panel Manufacturer in China
Cleanroom sandwich panels for Saudi Arabia and the UAE: types, supply and installation
Questions
Common questions
Which widths and thicknesses are PU panels listed in?
950 or 1,150 mm widths, and thicknesses of 40, 50, 75, 100, 150, 200 or 250 mm. Confirm the profile, effective cover width, length and delivery dimensions in the quotation.
Is a phenolic panel the same as a PU panel?
No. State whether phenolic refers to the core or the facing. Do not apply PU sizes or test results to a phenolic or PIR configuration. Ask us to confirm current availability and the offered construction.
Can PU panels be used for cleanroom walls and ceilings?
Yes, for partitions, ceilings and insulated enclosures. Confirm the face finish, joint sealing, cleaning compatibility and acceptance requirements. Ceiling loads and accessories need a separate assessment.
What thickness of PU panel do I need for a cleanroom?
No cleanroom standard sets one. Thickness follows the insulation you need, the wall height or ceiling span, and the door and window frames, which we list for 50, 75 and 100 mm walls. Send the room temperatures and heights and we will propose a thickness with the section drawing.
Is a PU panel allowed in a fire zone?
That depends on your local fire rules and insurer, and on the fire report for the exact panel. PU is an organic foam, and its class depends on formulation. Where a non-combustible core is required, use rock wool or hollow MgO panels.
Can PU panels be used for cold rooms?
Yes, PU is usually chosen for insulation, including cold rooms. Send the temperatures and humidity on both sides of each wall and ceiling, the floor build-up and the openings, and agree who designs condensation control.
What is the difference between a PU cleanroom panel and a PU cold room panel?
The core can be the same. A cleanroom wall adds the cleanroom requirements: smooth, cleanable faces, sealed joints, flush door and window frames and sealed penetrations. State both sets of requirements if the room is a cold cleanroom.
Do you make the PU panels yourselves?
Yes. We manufacture PU panels in our factory in Binhai New Area, Tianjin, on the same site as our rock wool and handmade cleanroom panels.
How do I compare the insulation of PU panels from different suppliers?
Ask each one for the declared thermal conductivity or U-value of the exact panel and thickness, on the same basis, and compare those figures. A thickness alone does not tell you the insulation.
Where are PU cleanroom panels used?
Where insulation is the main need and the fire rules allow a foam core: cold rooms, chilled process rooms, temperature-controlled stores, insulated enclosures, partitions, and cleanroom walls and ceilings in air-conditioned rooms.
How do PU panels compare with rock wool, MgO and honeycomb panels?
PU is light and chosen for insulation, but it is an organic foam whose fire class depends on the formulation and the test. Rock wool and hollow MgO are non-combustible cores, and honeycomb is light for dry rooms. See the panel selection guide.
How are PU panels installed?
In the usual panel order: floor track, walls, corners, ceiling, doors and windows, penetrations, then the final seal. In cold rooms every opening and penetration is sealed as it is installed. On turnkey contracts our own crew installs; on supply-only orders your crew works from our numbered drawings and installation guide, with video support.
How are PU panels packed for shipping?
Cut to length, numbered to the layout drawing and packed on timber pallets, with a packing list that follows the panel numbering. Your inspection company can check the goods before loading. See how to import a cleanroom from China.
What thickness of PU panel does a freezer room need?
As a reference, a −20 °C freezer with +45 °C outside is a 65 °C difference, which a 150 mm panel holds at the common 10 W/m² design limit if the core λ is 0.022 W/(m·K). A +2 °C chilled room in the same climate needs about 100 mm. The refrigeration designer's load calculation sets the final figure.
Project enquiry
Send what you have
A room list, a floor plan or only the floor area is enough to start. After you submit, send drawings by email or WhatsApp.
We reply by email within one working day. We can sign an NDA before you send drawings.