ZY CleanroomTIANJIN · SINCE 2002 Get a budget range
Cleanroom panels stacked on a pallet ready to ship

PU Cleanroom Panels: Sandwich Panels for Cleanrooms and Insulated Rooms

PU panels are tongue-and-groove sandwich panels with a polyurethane foam core between metal faces. Buyers use them for partitions, cleanroom walls and ceilings, and insulated enclosures. They are made in our own factory in Binhai New Area, Tianjin, on the same site as our rock wool and handmade cleanroom panels. PU panels are our insulation-led panel. Use them for cleanroom walls and ceilings where the room is held at a different temperature from the space around it, such as cold rooms, chilled process rooms and temperature-controlled stores, and where your fire rules allow a foam core. Where a non-combustible core is required, compare rock wool in the same width series.

Best for

  • Partition walls
  • Cleanroom walls and ceilings
  • Insulated enclosures
  • Temperature-controlled rooms

Specifications

Typical specification

CorePolyurethane (PU) foam
Width series950 mm or 1,150 mm (effective cover width is confirmed in the quotation)
Listed thicknesses40, 50, 75, 100, 150, 200 and 250 mm
Metal facesColour-coated, galvanized or embossed steel
JointMale-female tongue-and-groove
LengthSet by your panel schedule; manufacturing and transport limits are confirmed in the quotation
PIR and phenolicAvailability confirmed on request. PU sizes do not apply to them
Thermal and fire documentsRequested per model and tested assembly
Model codesHA-PU-TG950/40 to /250 and HA-PU-TG1150/40 to /250 (14 codes, see table below)

Options

What you can specify

  • 950 or 1,150 mm width series
  • Seven listed thicknesses from 40 to 250 mm
  • Colour-coated, galvanized or embossed steel faces
  • PIR or phenolic core, availability confirmed on request
  • Cut lengths to your panel schedule

How to choose a PU panel

PU panels are lighter than rock wool and are usually chosen for insulation, for example in cold rooms. Where a non-combustible core is required, compare rock wool cleanroom panels in the same width series.

PU, PIR and phenolic are different cores. State which one you need, and whether phenolic refers to the core or to the facing. Thermal and fire performance belong to the tested assembly, so ask for model-specific documents.

For the whole wall system, see cleanroom wall panels and all cleanroom sandwich panels.

Where PU cleanroom panels are used

PU is the core we propose when insulation is the main job of the wall and your fire rules allow a foam core. Typical uses:

ApplicationWhy PUWhat to check
Cold rooms and chilled process roomsInsulation is the main need, and the panel is lighter than rock woolTemperature and humidity on both sides of each wall; who designs condensation control
Temperature-controlled stores and insulated enclosuresSeven listed thicknesses from 40 to 250 mm, chosen for the insulation you needThe declared thermal value for the exact thickness
Cleanroom walls and ceilings in air-conditioned roomsSmooth steel faces and tongue-and-groove joints in the 950 or 1,150 mm seriesFace finish, joint sealing and the cleaning agents used in the room
Cold cleanroomsOne wall can meet both the cold room and the cleanroom requirementsFlush door and window frames, sealed joints and sealed penetrations
Partition wallsA light panel for internal partitionsThe fire report for the exact panel if the partition separates fire zones

Where a non-combustible core is required, such as a fire-separating wall, start from rock wool cleanroom panels or hollow MgO panels.

Model codes

The catalogue lists one code per width and thickness. Put the code on your enquiry and ask for the section drawing.

Thickness950 mm series1,150 mm series
40 mmHA-PU-TG950/40HA-PU-TG1150/40
50 mmHA-PU-TG950/50HA-PU-TG1150/50
75 mmHA-PU-TG950/75HA-PU-TG1150/75
100 mmHA-PU-TG950/100HA-PU-TG1150/100
150 mmHA-PU-TG950/150HA-PU-TG1150/150
200 mmHA-PU-TG950/200HA-PU-TG1150/200
250 mmHA-PU-TG950/250HA-PU-TG1150/250

A width series name is not the effective cover width. Confirm the cover width on the section drawing before you count panels.

Which thickness?

No cleanroom standard fixes a panel thickness. Thickness follows the job the wall has to do:

  • Insulation. A room held well below or above the temperature of the space around it needs more insulation. Ask for the declared thermal value for the exact thickness, and compare suppliers on the same basis. Our thermal value comparison sheet shows how.
  • Span. Taller walls and longer ceiling spans need a stiffer panel. Ask for an assembly-specific span or load check; thickness alone does not set a ceiling load.
  • Frames and openings. Our door frames and observation windows are listed for 50, 75 and 100 mm walls. If you choose another thickness, ask how doors and windows will be fitted.

PU panels for temperature-controlled cleanrooms and cold rooms

A room held below the temperature of the space around it has two jobs: keep the heat out and keep moisture from condensing in the wrong place. The panel is only part of the answer. Send these with the enquiry:

SendWhy
Room temperature and relative humidity insideSets the insulation and the condensation check
Temperature and relative humidity on the other side of each wall and the ceilingEach side of a wall can see different conditions
Floor build-upAn insulated room loses heat through an uninsulated floor
Ceiling: hung or self-supporting, and the void conditions aboveA low-temperature ceiling may need a thermal-break design
Doors, windows and pass boxes in the cold wallsEvery opening is a thermal and air-leak path
Penetrations for pipes, refrigerant lines and cablesEach one must be sealed

Our cleanroom ceiling range includes low-temperature thermal-break ceilings. Agree in the quotation who is responsible for the condensation-control design. A panel described as insulated does not by itself make an assembly condensation-free.

Cold room panel thickness by temperature difference

One design check used for cold stores limits the heat conducted through the walls to about 10 W/m². Dividing that limit by the panel's U-value gives the largest temperature difference a panel can hold. The table uses a core-only U-value from λ = 0.022 W/(m·K), the most common published PIR figure, so it errs on the thick side.

Panel thicknessCore-only U-value, W/(m²·K)Largest temperature difference at 10 W/m²Example that fits
75 mm0.29About 34 °CChilled room at +2 °C, +30 °C outside
100 mm0.22About 45 °CChilled room at +2 °C, +45 °C outside
150 mm0.15About 68 °CFreezer at −20 °C, +45 °C outside
200 mm0.11About 91 °CBlast freezer at −35 °C, +45 °C outside

This is for early sizing only. The refrigeration designer's heat-load calculation sets the final thickness, and the floor, doors and ceiling need their own check.

Comparing insulation between quotes

Ask every supplier for the declared thermal conductivity (λ, in W/m·K) or the declared U-value of the exact panel and thickness, measured on the same basis. Then compare like with like.

Worked example, assumed values: a core with λ = 0.022 W/m·K, 100 mm thick, has a core-only U of about 0.022 ÷ 0.100 = 0.22 W/m²·K. At 50 mm it is about 0.44 W/m²·K. The faces, joints and surface resistances change the final figure, so use the declared value for the panel, not this arithmetic, in your design. The 0.022 is an assumption for the example, not a declared value for our panels.

Industry reference values for PU and PIR panels

The main European panel makers publish these figures for panels with a polyurethane-family core, mostly PIR. They are industry reference values, not test results for our panels. Use them to check that a quotation is in a sensible range, and design with the value declared for the panel you buy.

PropertyIndustry reference rangeHow to read it
Thermal conductivity λ of the core0.018–0.022 W/(m·K), declared aged valueMost published PIR figures are 0.022; values near 0.018 come from proprietary core formulations
U-value, 50 mm panel0.38–0.51 W/(m²·K)Calculated by the EN 14509 method, which includes the joints
U-value, 75 mm panelNot published; core-only estimate 0.24–0.29 W/(m²·K)Our own arithmetic, λ divided by thickness
U-value, 100 mm panel0.18–0.22 W/(m²·K)EN 14509 method
U-value, 150 mm panel0.12–0.15 W/(m²·K)EN 14509 method
Core density38–40 kg/m³Published by several makers
Reaction to fire, EN 13501-1PIR panels are commonly classed B-s1,d0 or B-s2,d0; some products are classed lowerA class belongs to one tested product, face and thickness. The class of our PU panels waits for the factory test report

PU or rock wool?

PU panelRock wool panel
CoreOrganic foamNon-combustible mineral wool
WeightLighterHeavier
Usually chosen forInsulation, cold rooms, insulated enclosuresFire-separating walls, rooms where a foam core is not allowed
Widths950 or 1,150 mm series950 or 1,150 mm series; handmade 1,180 mm
Thicknesses40–250 mm40–250 mm (tongue-and-groove); 50 mm standard handmade
Fire classDepends on formulation; ask for the reportAsk for the report on the exact build

If your fire rules or insurer do not allow a foam core, start from rock wool panels. For a full comparison, see the panel selection guide.

How PU compares with the other cores we make

CoreFire noteWeightInsulationUse it when
Rock woolNon-combustible mineral coreHeaviest of the mineral coresBetter than hollow MgOA combustible core is not allowed and insulation matters
Hollow MgONon-combustible inorganic coreMediumModerateYou want a lighter non-combustible panel in a dry room
PUOrganic foam; class depends on formulation and testLightUsed for insulation-led roomsInsulation is the main need and fire rules allow foam
Honeycomb (aluminium or paper)Depends on the coreLightConfirmed on the quotationLight partitions and ceilings with a support design

Fire rules set the shortlist. A core name does not give a fire rating. The rating belongs to the tested panel, so ask for the report that covers the faces, core and thickness on your quotation. For the Euroclass system, see our panel selection guide.

In short: PU leads on insulation and light weight; rock wool and hollow MgO are the non-combustible cores; honeycomb is light for walls and ceilings in dry rooms.

Installation notes for PU panels

The panels go up in the usual order for a panel cleanroom: floor and base track, wall panels, corners, ceiling, doors and windows, then lights, filters and penetrations, and a final seal and leak test. Each step and its check are in our cleanroom panel installation guide. The points that matter most for this core:

  • Set out from the cover width. Count panels with the effective cover width on the section drawing, not the 950 or 1,150 mm series name.
  • Leave room for tolerance. EN 14509 allows ±2 mm on the useful width, so ten panels can add up to 20 mm along a wall. Decide before set-out where the closing panel is cut.
  • Seal every opening in a cold wall. Doors, windows, pass boxes, pipes, refrigerant lines and cables are thermal and air-leak paths, so seal each one as it is installed.
  • Build the floor and ceiling as drawn. An insulated room loses heat through an uninsulated floor, and a low-temperature ceiling may need a thermal-break design.
  • Seal the room side. Joints are sealed on the room side with a sealant that tolerates the cleaning agents used in the room.

On turnkey contracts our own crew installs the panels, doors and ceilings. On supply-only orders your crew installs them with our numbered layout drawing and installation guide, and our engineer can join a WhatsApp video call to check set-out and the first panels.

Installation and what ships with the order

Each order can ship with numbered panels cut to length, a layout drawing, an installation guide in English, Spanish, Portuguese, Arabic or Russian, an accessory kit (floor tracks, aluminium profiles, corner coves, flashings, screws and sealant) and a WhatsApp video call with our engineer for set-out and the first panels. Panels are packed strapped and stacked on timber pallets. See installation support.

What goes wrong on site

A width series is not an effective cover width, so confirm it before you calculate quantities. Ceiling loads and accessories need a separate assessment. A panel does not set a room's ISO class by itself.

Test results for one core do not carry over to another. Do not apply PU data to a PIR or phenolic panel.

Packing and shipping to your site

Panels and doors are manufactured in our Tianjin factory, cut to length, numbered to the layout drawing and packed on timber pallets. The packing list follows the panel numbering, so each pallet can be matched to a zone of the layout on arrival. Other equipment is inspected before shipping, and your inspection company can check the goods before loading.

State the freight term and the port or site city in the quotation, and ask your broker to confirm the customs code before shipment. See how to import a cleanroom from China.

How to ask for a quotation: what to send

Send the destination country and a panel schedule with cut lengths. Give the required core, both metal faces, the effective cover width and the joint details. For cleanroom use, add the face finish, joint sealing, the cleaning agents used and your acceptance requirements. List trims, sealants, packing and any installation work you want in the scope.

Build the room list in our room list builder: area, target class or condition and pressure for each room. Send it with the items above on WhatsApp (+44 7962 561184) or through the form below. We reply with a scope list and a first budget range; the price is confirmed in a written quotation.

Quote checklist

SendWhy
Model code or width series and thicknessOne code per width and thickness
Panel schedule with cut lengths and quantitiesPanels are cut and numbered to the layout
Room temperatures, inside and outsideTo check the thickness against the insulation you need
Both faces: steel type, coating, colourColour-coated, galvanized or embossed
Core: PU, PIR or phenolicDifferent cores; test data does not carry over
Trims, sealants, floor and ceiling detailsListed in the scope so quotations compare line by line
Reports you needFire or thermal reports, for the exact build
Destination country and portPacking and freight

Cleanroom panel selection: core materials compared

How to Choose a Cleanroom Panel Manufacturer in China

Cleanroom sandwich panels for Saudi Arabia and the UAE: types, supply and installation

Questions

Common questions

Which widths and thicknesses are PU panels listed in?

950 or 1,150 mm widths, and thicknesses of 40, 50, 75, 100, 150, 200 or 250 mm. Confirm the profile, effective cover width, length and delivery dimensions in the quotation.

Is a phenolic panel the same as a PU panel?

No. State whether phenolic refers to the core or the facing. Do not apply PU sizes or test results to a phenolic or PIR configuration. Ask us to confirm current availability and the offered construction.

Can PU panels be used for cleanroom walls and ceilings?

Yes, for partitions, ceilings and insulated enclosures. Confirm the face finish, joint sealing, cleaning compatibility and acceptance requirements. Ceiling loads and accessories need a separate assessment.

What thickness of PU panel do I need for a cleanroom?

No cleanroom standard sets one. Thickness follows the insulation you need, the wall height or ceiling span, and the door and window frames, which we list for 50, 75 and 100 mm walls. Send the room temperatures and heights and we will propose a thickness with the section drawing.

Is a PU panel allowed in a fire zone?

That depends on your local fire rules and insurer, and on the fire report for the exact panel. PU is an organic foam, and its class depends on formulation. Where a non-combustible core is required, use rock wool or hollow MgO panels.

Can PU panels be used for cold rooms?

Yes, PU is usually chosen for insulation, including cold rooms. Send the temperatures and humidity on both sides of each wall and ceiling, the floor build-up and the openings, and agree who designs condensation control.

What is the difference between a PU cleanroom panel and a PU cold room panel?

The core can be the same. A cleanroom wall adds the cleanroom requirements: smooth, cleanable faces, sealed joints, flush door and window frames and sealed penetrations. State both sets of requirements if the room is a cold cleanroom.

Do you make the PU panels yourselves?

Yes. We manufacture PU panels in our factory in Binhai New Area, Tianjin, on the same site as our rock wool and handmade cleanroom panels.

How do I compare the insulation of PU panels from different suppliers?

Ask each one for the declared thermal conductivity or U-value of the exact panel and thickness, on the same basis, and compare those figures. A thickness alone does not tell you the insulation.

Where are PU cleanroom panels used?

Where insulation is the main need and the fire rules allow a foam core: cold rooms, chilled process rooms, temperature-controlled stores, insulated enclosures, partitions, and cleanroom walls and ceilings in air-conditioned rooms.

How do PU panels compare with rock wool, MgO and honeycomb panels?

PU is light and chosen for insulation, but it is an organic foam whose fire class depends on the formulation and the test. Rock wool and hollow MgO are non-combustible cores, and honeycomb is light for dry rooms. See the panel selection guide.

How are PU panels installed?

In the usual panel order: floor track, walls, corners, ceiling, doors and windows, penetrations, then the final seal. In cold rooms every opening and penetration is sealed as it is installed. On turnkey contracts our own crew installs; on supply-only orders your crew works from our numbered drawings and installation guide, with video support.

How are PU panels packed for shipping?

Cut to length, numbered to the layout drawing and packed on timber pallets, with a packing list that follows the panel numbering. Your inspection company can check the goods before loading. See how to import a cleanroom from China.

What thickness of PU panel does a freezer room need?

As a reference, a −20 °C freezer with +45 °C outside is a 65 °C difference, which a 150 mm panel holds at the common 10 W/m² design limit if the core λ is 0.022 W/(m·K). A +2 °C chilled room in the same climate needs about 100 mm. The refrigeration designer's load calculation sets the final figure.

Project enquiry

Send what you have

A room list, a floor plan or only the floor area is enough to start. After you submit, send drawings by email or WhatsApp.

We reply by email within one working day. We can sign an NDA before you send drawings.

WhatsApp +44 7962 561184 is our UK number for export enquiries. The factory is in Tianjin, China.

Fastest reply: message us on WhatsApp. Or use the form, and add your WhatsApp number so we can reply there.

Email: [email protected]
WhatsApp: +44 7962 561184

Step 1 of 2

Chat on WhatsAppGet a budget range