Buyer guide
Cleanroom Wall Panel Systems: What They Are Made Of and How They Fit Together
Most cleanroom walls are built from sandwich wall panels: two metal faces bonded to a core such as rock wool, MgO, PU or honeycomb. Cleanroom partitions are the same system: wall panels that divide a building into clean rooms and corridors. They stand in a floor track, lock together with aluminium profiles, and carry flush doors and windows. A cleanroom wall must be smooth, impervious and unbroken, with no hard-to-clean recesses, and its joints and penetrations must be sealed. Choose the core by your fire rules first. Then set the panel thickness and length from the wall height and the door and window frames, and send the wall schedule separately from the ceiling schedule.
By ZY Cleanroom · Updated · Sources at the end of the page
What cleanroom walls are made of
A cleanroom wall is judged by its surface and its seals, not by its name. EU GMP Annex 1 asks for exposed surfaces that are smooth, impervious and unbroken (para 4.5), with no recesses that are hard to clean (para 4.6), and for materials that tolerate repeated cleaning, disinfectant and sporicidal agents (para 4.7).
A sandwich wall panel meets this with a factory-finished metal face and a sealed joint:
| Layer | What it does | What to specify |
|---|---|---|
| Room-side face | The cleanable surface | Metal (colour-coated, galvanized or stainless steel), coating type, steel thickness, colour |
| Core | Stiffness, insulation and the panel's fire behaviour | Rock wool, hollow or handmade MgO, PU, or paper or aluminium honeycomb; density where relevant |
| Corridor-side face | Can differ from the room side | Metal, coating, thickness, colour |
| Edge and joint | Locks panels together and closes the gap | Centre aluminium connection, male-female, or tongue-and-groove |
Both faces are specified separately. Corridor and room sides are often different.
The core-by-core sizes we make are on our cleanroom sandwich panels page. For fire classes, see the panel selection guide: a core name does not give a fire rating, because the rating belongs to the tested panel.

Cleanroom wall panel system components: panels, profiles, coving, doors and windows
A wall is a system, not only panels. Our panel orders can ship with:
| Part | Where it goes |
|---|---|
| Floor track | Fixed to the finished floor; the panels stand in it |
| Wall panels, cut to length and numbered | Set out to the layout drawing |
| H-connectors and channels | Join panels in a run and close the top and ends |
| Corner posts | External and internal wall corners |
| Inner and outer curved coving | Wall-to-wall, wall-to-floor and wall-to-ceiling junctions, so there is no sharp corner to clean |
| Door and window sections | Frame openings flush with the panel face |
| Flashings, screws and sealant | Closing details and sealed joints |
| Return-air wall modules | Wall sections that carry return-air grilles and ducts; mark their position and the airflow from the HVAC design |
| Removable wall panels | Where equipment must come in or out later; mark the removal direction and who reseals the panel |
| Stainless steel wall bases | At the floor junction in rooms that are wet-cleaned |
The profiles, coving, flashings and sealant ship as an accessory kit with the numbered panels, sized to the layout, so a wall can be built from one delivery. Door and window frames are made for the same wall thickness and ship in the same order; the openings are planned below.
The usual sequence is floor track, wall panels, corners, ceiling, doors and windows, then lights, filters and penetrations, then the final seal and a leak test. China's cleanroom construction code, GB 50591-2010, lists its decoration work in the same order. See the panel installation guide for tolerances and sealing.
Wall height, panel length and thickness
On our handmade cleanroom panel, the length is cut from 100 to 6,000 mm, so a wall up to that height can usually be one panel from floor track to ceiling. The width is 1,180 mm as standard and the thickness 50 mm as standard. Rock wool and PU tongue-and-groove panels are also made in 950 and 1,150 mm series from 40 to 250 mm.
No cleanroom standard fixes a wall panel thickness. It follows four things:
- The fire rule for that wall.
- The wall height and how the top of the wall is restrained.
- The insulation needed between rooms at different temperatures.
- The door and window frames: ours are listed for 50, 75 and 100 mm walls.
Send the wall heights and the room temperatures, and we propose a thickness on the section drawing.
Doors, windows and pass boxes in the wall
Plan every opening with the panel layout, not after it. A door frame or window that stands proud of the wall leaves a ledge that collects dust, so cleanroom windows and door frames are set flush with the panel face. A room where walls, ceiling, doors and windows all sit flush in one system is often called a monobloc cleanroom. We manufacture cleanroom doors, including hermetic doors, with frames for 50, 75 and 100 mm walls. Vision panels and observation windows are supplied flush-fitted for the same wall thicknesses, and pass boxes are supplied in the same quotation, inspected before shipping.
Mark on the wall drawing: each opening's size and position, the door type and swing, the window size, and any pass box, so the panels are cut and framed at the factory.
Services and penetrations
Cables, pipes, switches and sockets all pass through the wall. USP <797> asks for every penetration through a ceiling or wall to be sealed, and for panels to be joined and sealed to each other and to the support structure. Mark penetrations on the drawing before the panels are cut. On hollow MgO panels, the hollow channels can carry small cables where the project allows; confirm this on the drawing.
Choosing the core for a wall
| If the wall | Compare first | Why |
|---|---|---|
| Must be non-combustible under your fire rules | Rock wool, MgO | Mineral or inorganic cores. Fire test reports for our rock wool cleanroom panels are available on request |
| Is washed down or in a humid room | Rock wool | Keep MgO and paper honeycomb cores away from standing water and humidity unless the core is rated for it |
| Separates rooms at very different temperatures | PU, or thicker rock wool | Insulation-led; PU only where your fire rules allow foam |
| Must be light, in a dry room | Honeycomb, hollow MgO | Lighter cores |
Where the project asks for thermal panels, the insulation comes from the core and its thickness: compare PU panels or thicker rock wool, and ask for the declared thermal value of the quoted panel.
This is a shortlist, not a rating. The fire report for the exact panel and the cleaning regime decide.
What to send for a wall panel quotation
| Send | Why |
|---|---|
| Floor plan with wall lines and room names | Panel layout and count |
| Wall heights, room by room | Cut lengths |
| Wall schedule, separate from the ceiling schedule | Walls and ceilings are quoted differently |
| Fire rule for each wall | Shortlists the core |
| Both faces: metal, coating, thickness, colour | Each side can differ |
| Joint type | Centre aluminium, male-female or tongue-and-groove |
| Doors, windows and pass boxes with sizes and positions | Openings are framed at the factory |
| Cleaning and disinfectant agents | Coating and sealant must tolerate them |
| Destination country and port | Packing and freight |
If you only have a floor plan with the floor area, that is enough to start. Chat on WhatsApp (+44 7962 561184) or use the room list builder.
Questions
Common questions
What are cleanroom walls made of?
Most are sandwich panels: two metal faces bonded to a core such as rock wool, MgO, PU or honeycomb. The faces give a smooth, cleanable surface and the joints are sealed, as EU GMP Annex 1 and USP <797> ask.
Is a cleanroom partition the same as a cleanroom wall panel?
Yes. A cleanroom partition is a wall built from cleanroom sandwich panels to divide rooms and corridors. It is specified the same way: core, both faces, joint, wall height, openings and penetrations.
What is a cleanroom wall panel system?
The panels plus the parts that hold and seal them: floor track, H-connectors and channels, corner posts, curved coving, flush door and window frames, flashings and sealant.
How tall can a cleanroom wall panel be?
Our handmade cleanroom panel is cut from 100 to 6,000 mm long, so a wall up to that height can usually be a single panel. The length you are offered is confirmed on the section drawing.
What thickness should a cleanroom wall panel be?
No cleanroom standard sets one. It follows the fire rule, the wall height, the insulation needed and the door and window frames, which we list for 50, 75 and 100 mm walls.
Can cleanroom wall panels take disinfectants?
Ask for the face coating and the sealant to be checked against the agents you use. EU GMP Annex 1 para 4.7 asks for materials that tolerate repeated cleaning, disinfectant and sporicidal agents.
Do you make cleanroom wall panels?
Yes. We manufacture rock wool, MgO, PU and honeycomb cleanroom sandwich panels for walls, and cleanroom doors, in our factory in Binhai New Area, Tianjin, in production since 2002, with 4 panel lines.
Related guides
- How to audit a cleanroom panel factory, on site or by video
- How to Specify a Hermetic Door: When It Must Hold Room Pressure
- Cleanroom Door Sizes and Specifications: What Goes in the Door Schedule
- Modular operating theatres: scope, air and pressure standards
- Rock Wool Sandwich Panels
- Hollow MgO Cleanroom Panels
- Honeycomb Core Panels
- PU Sandwich Panels
- Turnkey cleanroom contractor
- Room list builder
Sources
- GB 50591-2010, Code for Construction and Acceptance of Cleanroom (issued 15 July 2010, in force 1 February 2011; contents list, chapter 4 and Appendices E and G; checked 1 November 2026)
- EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products (published 25 August 2022, applied from 25 August 2023; checked 1 November 2026)
- Washington State Department of Health, Pharmacy Self-Inspection Worksheet, 2026 USP 797 Sterile Compounding Addendum, DOH 690-296 (January 2026), which reproduces USP <797> text by section; checked 1 November 2026
Project enquiry
Send what you have
A room list, a floor plan or only the floor area is enough to start. After you submit, send drawings by email or WhatsApp.
We reply by email within one working day. We can sign an NDA before you send drawings.
WhatsApp +44 7962 561184 is our UK number for export enquiries. The factory is in Tianjin, China.
Fastest reply: message us on WhatsApp. Or use the form, and add your WhatsApp number so we can reply there.
Email: [email protected]
WhatsApp: +44 7962 561184