Monobloc Cleanrooms: Flush, Integrated Panel Rooms

A monobloc cleanroom is a trade name, used mainly in the UK, for a cleanroom built as one integrated panel system: factory-made wall and ceiling panels, with doors, windows, coving and service openings designed to sit flush with the wall face. No standard defines the term, and ISO 14644-4 does not prescribe any construction method, so judge a monobloc room by the same things as any hardwall cleanroom: flush, sealed, cleanable surfaces and test results against its class. Choose one when rooms are cleaned often, as in pharmaceutical, hospital and laboratory work, and every ledge or open joint would be a cleaning problem.

By ZY Cleanroom · Updated · Sources at the end of the page

What "monobloc" usually means

Buyers and suppliers use the word for a room where every part of the envelope is part of one system:

FeatureWhat to look for
Wall and ceiling panelsFactory-made, flat faces, joints closed and sealed
DoorsFrames and leaves flush with the wall face; flush vision panels
WindowsGlazing flush with the wall face on the clean side
Corners and floor junctionCoved or sealed, with no ledge
ServicesOpenings for switches, outlets, gas and ducts planned in the panel layout and sealed
CeilingSealed to the walls; openings for filters and lights cut to the layout

The point of all of these is cleaning. EU GMP Annex 1 asks for exposed surfaces that are smooth, impervious and unbroken (para 4.5), with no recesses that are hard to clean (para 4.6), materials that take repeated cleaning and disinfectants (para 4.7), and ceilings sealed against the space above (para 4.8). A flush, integrated system is one way to meet those rules.

Monobloc Cleanrooms: Flush, Integrated Panel Rooms

Monobloc, modular, softwall and built rooms

TypeHow it is builtTypical fit
Monobloc (flush panel system)Factory-made panels, doors and windows from one system, assembled on site with flush detailsPharmaceutical, hospital, laboratory and other rooms cleaned often
Modular panel roomFactory-made wall and ceiling panels on a floor track inside an existing building; the term does not imply every detail is flushMost hardwall cleanrooms; the same panels can be built to a flush specification
Softwall or portable boothCurtains or light panels on a frame, with fan filter unitsLocal, temporary or lower-risk work where no rule demands fixed walls
Conventional (built on site)Masonry or stud-and-board walls with applied finishesIrregular buildings, heavy fixtures; quality depends on site finishing

The words overlap. "Monobloc" and "modular" are often used for the same kind of panel room; what matters is the specification, not the label. ISO 14644-4:2022 does not prescribe specific technological or contractual means, and the same ISO 14644 tests apply to every type. See modular vs conventional cleanrooms and hardwall vs softwall.

What to specify for a flush, integrated room

Write these into the enquiry or URS, so every supplier quotes the same thing:

  • Panel system: core, both faces, thickness and joint type; walls and ceiling from one system.
  • Doors: frames and leaves flush with the wall face; flush vision panels; hermetic doors where closed-door leakage must be low.
  • Windows: flush on the clean side; single or double glazed.
  • Coving: at wall-to-floor and wall-to-wall corners, or a sealed joint.
  • Ceiling: sealed to the walls; walkable if filters and ducts are serviced from above.
  • Services: every opening shown on the panel layout, cut at the factory and sealed.
  • Sealant: named for each joint, and compatible with your cleaning agents.
  • Tests: classification to ISO 14644-1 in the agreed state, plus pressure, airflow and filter leak tests.

Junction by junction: the Annex 1 basis and what to check

Annex 1 states its surface rules for the room as a whole. A flush specification carries them down to each junction, and the same list serves as a walk-down when the room is handed over.

JunctionAnnex 1 basisWhat to check at handover
Wall panel jointsPara 4.5: exposed surfaces smooth, impervious and unbrokenEach joint closed along its full length; the sealant bead continuous, with no gaps
Wall to floor and wall to wall cornersPara 4.6: no recesses that are difficult to cleanCoving fitted where specified, or a sealed joint; no step between the coving and the wall face
Wall to ceiling and ceiling openingsPara 4.8: ceilings designed and sealed against the space abovePerimeter sealed all round; filter, light and access openings sealed into the ceiling
DoorsPara 4.6: doors designed to avoid recesses that cannot be cleaned; sliding doors may be undesirable for this reasonFrame flush with the wall face; on a sliding door, the track and the gap behind the leaf can be reached for cleaning
Windows and vision panelsPara 4.6: projecting ledges kept to a minimumGlazing flush on the clean side, with no glazing bead standing proud
Service openingsParas 4.5 and 4.7: unbroken surfaces; materials that take repeated cleaning, disinfectant and sporicidal agentsEvery opening matches the panel layout and is sealed; plates and covers suit the cleaning agents
Sinks and drainsPara 4.9: none in grade A and B areas; air breaks elsewhere, and traps or water seals on floor drainsPlaced only in rooms whose grade allows them
Pass-through sterilisersPara 4.11: where possible, double-ended sterilisers sealed into the wallThe wall opening framed and sealed to the equipment

Walk the room before the ISO 14644 tests, while joints can still be resealed. The particle count and pressure tests do not look for an open joint or a ledge, so a room can pass them and still be hard to clean. Agree in the contract who records and fixes what the walk-down finds.

Our flush panel system

We manufacture the parts of a flush cleanroom envelope in our factory in Tianjin:

PartWhat we make
Wall and ceiling panelsHandmade cleanroom panels, 1,180 mm wide and 50 mm thick as standard, cut from 100 to 6,000 mm, with rock wool, MgO, PU or honeycomb cores and colour-coated or stainless steel faces; centre aluminium or male-female joints
DoorsSwing, sliding and hermetic doors, manual or automatic, with frames for 50, 75 and 100 mm panel walls and flush double-glazed vision panels
CeilingsWalkable sandwich panel ceilings and T, I and Z grid ceilings
ProfilesAluminium channels, corner posts, inner and outer curved coving, door and window sections

Cleanroom vision panels and observation windows, pass boxes, air showers and FFUs are supplied in the same quotation and inspected before shipping. Panels are numbered to a layout drawing, and on turnkey projects abroad our own crew installs and commissions the room. Fire test reports for rock wool panels are available on request.

The fastest way to start is to chat on WhatsApp (+44 7962 561184) and send your room list; or use our room list builder and the form below.

Questions

Common questions

What is a monobloc cleanroom?

A trade name for a cleanroom built as one integrated panel system: factory-made walls and ceiling with doors, windows, coving and service openings fitted flush. It is not defined in ISO 14644 or EU GMP.

When should I choose a monobloc cleanroom?

When rooms are cleaned often and every ledge matters: pharmaceutical, hospital and laboratory rooms are the typical fit. A softwall booth can suit local, temporary or lower-risk work, and a room built on site can suit an irregular building or heavy fixtures. Whatever the label, write the flush details into the specification and judge the room by its test results.

Is a monobloc cleanroom the same as a modular cleanroom?

Often the terms describe the same kind of factory-made panel room. "Monobloc" stresses the flush, integrated finish. Compare suppliers on the written specification, not on the name.

Is a monobloc cleanroom GMP compliant?

No construction type is compliant by itself. EU GMP Annex 1 sets surface rules, and the finished room is judged by its qualification and test results. GMP approval belongs to the manufacturer and its regulator.

Why are flush doors and windows used in cleanrooms?

A frame or glazing bead that stands proud of the wall leaves a ledge that holds dust and is hard to clean. EU GMP Annex 1 asks for surfaces with no recesses that are hard to clean.

What should I check in a monobloc cleanroom at handover?

Walk every junction before the ISO 14644 tests: panel joints closed and sealed, coving or sealed corners, the ceiling sealed at its edges and openings, door frames and glazing flush on the clean side, and service openings sealed. The particle tests do not find an open joint or a ledge.

Can a monobloc cleanroom be moved or extended later?

Panel rooms can be rearranged or extended within the limits of the system, because the panels are made to a layout and assembled on site. A changed layout needs new panels cut to the new drawing.

Do you supply monobloc cleanrooms?

Yes, as a flush panel system. We manufacture the wall and ceiling panels, doors and ceilings in our factory in Tianjin, and supply observation windows, pass boxes, air showers and FFUs in the same quotation. On turnkey projects abroad our own crew installs and commissions the room.

Related guides

Sources

Project enquiry

Send what you have

A room list, a floor plan or only the floor area is enough to start. After you submit, send drawings by email or WhatsApp.

We reply by email within one working day. We can sign an NDA before you send drawings.

WhatsApp +44 7962 561184 is our UK number for export enquiries. The factory is in Tianjin, China.

Fastest reply: message us on WhatsApp. Or use the form, and add your WhatsApp number so we can reply there.

Email: [email protected]
WhatsApp: +44 7962 561184

Step 1 of 2

Chat on WhatsAppGet a budget range