Pass box qualification: DQ, IQ, OQ and PQ

Pass box qualification follows the EU GMP Annex 15 chain: URS, DQ, IQ, OQ and PQ, each proving one more thing about the box. The annex lists no pass box tests, so the owner's protocol sets them.

By ZY Cleanroom · Updated · Sources at the end of the page

The stages

This guide uses the 2015 text of Annex 15. EMA opened a revision with a concept paper in 2026 and proposes final publication in April 2028, so check the version in force.

StageWhat Annex 15 asksExample evidence for a pass box
URS (para 3.2)A written specification, kept as the reference for the whole life cycleSize, grades of both rooms, interlock type, material list
DQ (para 3.3)Design shown to comply with GMP and the URSDrawings, filter grade, interlock logic
FAT and SAT (paras 3.4 to 3.7)Tests at the vendor, then on site where usefulFactory test record
IQ (paras 3.8 and 3.9)Installed as drawn, supplier instructions collected, instruments calibrated, materials verifiedWall seal check, serial numbers, gauge certificates
OQ (paras 3.10 and 3.11)Operates as designed, with upper and lower limits testedInterlock, airflow, filter leak test, pressure
PQ (paras 3.13 and 3.14)Performs effectively and reproducibly, with production or simulated materialParticle counts, recovery, loaded transfer
Pass box qualification: DQ, IQ, OQ and PQ

Combining and reusing tests

Annex 15 (para 3.6) lets some FAT tests stand in for IQ and OQ where justified, if transport and installation do not affect them. Depending on the complexity of the equipment, OQ may be run with IQ as one IOQ (para 3.10). PQ may sometimes run with OQ (para 3.13). A successful OQ lets the owner finalise operating and cleaning procedures, operator training and maintenance needs (para 3.12).

What Annex 1 says about the box itself

Annex 1 (para 4.12) asks that pass-through hatches protect the higher-grade side, for example by flushing with an active filtered air supply. Only items on an approved list, assessed during validation of the transfer process, go through into grade A or B. So PQ should cover the transfer process, not only the empty box.

Para 4.13 says the entry and exit doors of hatches and airlocks should not open together. It asks for interlocks on airlocks leading to grades A and B, and at least a warning for grades C and D. Decide in your protocol how that wording applies to the box.

Example: OQ and PQ test list

Example only. Neither annex lists pass box tests. Annex 1 (para 4.25) lists tests for cleanrooms and clean air equipment. An active box with its own fan and filter can borrow from it.

OQ: interlock works both ways, indicators and alarms work, airflow at the filter, filter leak test, and pressure difference to each room. PQ: particle count in the chamber at rest against the grade the owner sets, recovery after a disturbance, and transfer of approved items. Include the disinfection step from the contamination control strategy.

Requalification

Annex 15 (para 4.1) asks for evaluation at a suitable frequency to confirm the equipment stays in a state of control. If the owner treats the box as clean air equipment, Annex 1 (para 4.32) applies. It caps requalification at 6 months for grades A and B and 12 months for grades C and D. A change of final filters is a change to consider.

Documents to request

Ask for the documents that let you finish IQ. Annex 15 names drawings and specifications, supplier operating and maintenance instructions, instrument calibration and materials of construction. Add the filter test certificate, the interlock description and the factory test record.

Who approves the room

Your regulator or customer auditor judges the facility, not the contractor. The owner approves the protocol and the results. To have a room list reviewed, send it to ZY Cleanroom, a cleanroom design-and-build contractor.

Questions

Common questions

What is the difference between IQ and OQ for a pass box?

IQ checks the box was installed as drawn, with instruments calibrated and materials verified. OQ checks it works as designed, including its upper and lower limits (Annex 15, paras 3.9 and 3.11).

Can the factory test replace tests on site?

Only where appropriate and justified, and when transport and installation do not affect the function (Annex 15, para 3.6).

Does a pass box without a fan need qualification?

Annex 1 asks that hatches protect the higher grade and that transfers are validated. How much testing a box without a fan needs is the owner's decision, set by risk.

Who writes the qualification protocol?

The owner. FDA (2004) keeps drug manufacturers responsible for test methods and acceptance criteria when contractors certify air systems. Annex 15 (para 2.6) says site staff should confirm a third party's protocol is suitable before approval, so a supplier can offer a draft.

How do you validate a UV pass box?

Annex 1 says ultraviolet irradiation is not an acceptable method of sterilisation (para 8.71), so do not rely on the lamp as the transfer control. Qualify the box as you would any other, then add checks on lamp output, lamp hours and the timer interlock. The owner decides by risk whether the lamp is kept at all.

How do you validate a VHP pass box?

Annex 1 (para 4.36) says the effectiveness of a vapour agent and its dispersion system should be understood and validated. In practice, this means developing the cycle, proving distribution with biological indicators at the worst positions, and confirming aeration to a safe residual level. The owner's quality team approves the protocol and the result.

Related guides

Sources

Project enquiry

Send what you have

A room list, a floor plan or only the floor area is enough to start. After you submit, send drawings by email or WhatsApp.

We reply by email within one working day. We can sign an NDA before you send drawings.

WhatsApp +44 7962 561184 is our UK number for export enquiries. The factory is in Tianjin, China.

Email: [email protected]
WhatsApp: +44 7962 561184

Step 1 of 2

WhatsAppGet a budget range