Operating Theatre Zones: Rooms, Pressure and Flow

An operating theatre suite is planned as zones that step from the most protected rooms, where sterile instruments are laid up and surgery takes place, out through scrub, anaesthetic and corridor areas to the dirty utility and disposal route. UK guidance names four room cleanliness categories, sterile, clean, transitional and dirty, and sizes the air so it flows from cleaner rooms to less clean ones. Pressure, doors and the routes for staff, patients, clean supplies and waste all follow from that order.

By ZY Cleanroom · Updated · Sources at the end of the page

The zones of an operating suite

UK HTM 03-01 uses four room cleanliness categories: sterile, clean, transitional and dirty. The design assigns each room of your suite to one of them, and the air system keeps the flow moving from the cleaner category to the less clean one.

In HTM 03-01 standard layout 1, the pressures show the order of the main rooms:

RoomPressure in standard layout 1Position in the order
Lay-up preparation room35 PaHighest: air flows from here into the theatre
Operating theatre25 Pa nominalBelow the preparation room
Scrub25 PaSame level as the theatre
Corridors and support roomsLowerAir flows out to them
Dirty utility and disposalLower pressure; door kept closedLowest: air flows in, not out

Write the category and pressure of every room on the room list, so the zone order is fixed before the walls and doors are made.

Operating Theatre Zones: Rooms, Pressure and Flow

The four operation theatre zones used in India

Indian hospital guidance divides the operation theatre complex into four zones by the level of cleanliness and sterility needed. The national IPC guidelines (2020) used in NCDC training name them unrestricted, semi-restricted, restricted and disposal. The CBSE health care workbook, and much Indian hospital teaching, names the same four protective, clean, aseptic and disposal. Both lists run in the same order: from the entry, inward to the operating rooms, then out by the disposal route.

OrderNational IPC guidelines, 2020Common nameRooms in the zone
1, outermostUnrestricted zone or clean areaProtective zoneStaff changing rooms, patient waiting and reception, administration, stores and records, receiving area for materials and equipment
2Semi-restricted zone or sub-sterile areaClean zonePre-operating room, recovery room, store for sterile equipment and consumables
3, innermostRestricted zone or sterile areaAseptic or sterile zoneOperating rooms, scrub and gowning, pre-anaesthesia room, sterile instrument trolley area
4Disposal zone or areaDisposal zoneDirty utility and disposal corridor, kept outside the aseptic zone

The same guidelines ask for smooth, impervious work surfaces of non-porous material without crevices, and non-slip, water-impervious flooring with sealed joints. For the walls and ceilings of the restricted zone, that means flush panels with sealed joints and no ledges; see panel installation for how the joints are sealed.

Indian zone names do not set pressures. NABH (2018) gives at least 2.5 Pa between the operation theatre and the adjoining areas, as in the table below. Whichever names your hospital uses, write each room's zone and pressure on the room list before the walls and doors are made.

How air and pressure step between zones

Air should always move from a cleaner zone to a less clean one. HTM 03-01 gives the open-door airflow needed for each pair, for a single door of 0.80 × 2.01 m and a double door of 1.80 × 2.01 m:

From → toSingle door, m³/sDouble door, m³/s
Sterile → dirty0.470.95
Sterile → transitional0.390.75
Sterile → clean0.280.57
Clean → dirty0.390.75
Clean → transitional0.280.57
Transitional → dirty0.280.57

Pressure values come from the standard of the country where the hospital is built:

SourcePressureNote
UK HTM 03-01 Part A, standard layout 1Theatre 25 Pa nominal, scrub 25 Pa, lay-up preparation room 35 PaThe preparation room sits above the theatre
India NABH, 2018At least 2.5 Pa against adjoining areas
US ASHRAE/ASHE 170Positive, no value given20 total and 4 outdoor air changes per hour

When a door opens, the pressure across it is lost, so the air system also has to give open-door protection (HTM 03-01 para 8.18). A suite that may be used for infectious cases can run the theatre at the same pressure as its corridor, with no air cascading out (para 8.125).

The operating zone inside the theatre

Some codes also zone the theatre itself. China's GB 50333-2013 ranks clean operating rooms I to IV by surgery type, and gives the operating zone a cleaner class than the area around it: for a Class I room, class 5 at the operating zone and class 6 around it; for Class II, class 6 and class 7; for Class III, class 7 and class 8; Class IV is class 8.5.

For ultra-clean ventilation, HTM 03-01 asks for a clean zone of at least 2.8 × 2.8 m under the canopy for major orthopaedic work, marked on the floor by a contrasting inlay in the floor covering. A line drawn on the floor is not accepted at validation. See operating room laminar flow ceilings.

Four routes through the zones

Plan each route on the layout before the walls are fixed:

  • Staff: changing room → clean corridor → scrub → theatre.
  • Patient: reception or holding → anaesthetic room → theatre → recovery.
  • Clean supplies: sterile store → preparation (lay-up) room → theatre.
  • Used instruments and waste: theatre → dirty utility → disposal route, kept apart from the clean supply route.

Where a route has to cross a zone boundary often, put a door that holds the pressure on that boundary.

Doors at each zone boundary

OpeningUsual door
Theatre main entrance (bed and trolley)Hermetic sliding, automatic
Scrub room to theatreHermetic sliding or swing, automatic or with push plates
Preparation (lay-up) room to theatreSwing or sliding, self-closing
Anaesthetic roomSliding or swing, self-closing
Dirty utility / disposalSwing, self-closing; kept closed
Suite entrance from the hospitalAutomatic sliding or swing, self-closing

Dubai Health Authority guidance says hold-open devices should not be fitted to doors of pressurised rooms, and that sliding doors should hang from a top track with no floor track. We make hermetic sliding and swing doors, manual or automatic, in our own factory in Tianjin. See operating theatre doors and hermetic cleanroom doors.

Operating room or operating theatre?

The two terms mean the same room: "operating theatre" is common in UK and Commonwealth usage, "operating room" in US usage. "Operating suite" or "operating department" means the theatre with the rooms around it, which is the area zoned on this page.

"Operation theatre" is a further form of the same term in common use, and an operation theatre zone is one of the zones of the suite described on this page.

What we supply for an operating suite

We manufacture the wall and ceiling panels and the hermetic and swing doors for the suite. Observation windows, pass-through hatches, ceiling air diffusers with terminal filters and other air equipment are supplied in the same quotation and inspected before shipping. On turnkey projects abroad our own crew installs the envelope and installs and commissions the HVAC, and we provide the IQ and OQ documents. Licensed medical gas and electrical work is done by a licensed local contractor named in the contract. Your health authority approves the facility.

What to send for a quote

SendWhy
Floor plan of the suite, with room namesZones and routes
Surgery types per theatreSets the class or the UCV need
The standard your health authority usesPressure and air values
Ceiling void heightCanopy and ducts
Bed and trolley sizesDoor clear openings
Whether the hospital stays open during workPhasing
Site country and cityDelivery and site work

The fastest way to start is to chat on WhatsApp (+44 7962 561184) and send the suite plan; or use our room list builder and the form below.

Questions

Common questions

What are the zones of an operating theatre?

UK HTM 03-01 uses four room cleanliness categories: sterile, clean, transitional and dirty. The suite steps from the preparation room and theatre, which run at the highest pressure, out to corridors and support rooms, and finally to the dirty utility and disposal route at the lowest.

What are the four zones of an operation theatre in India?

Protective, clean, aseptic (sterile) and disposal. India's national IPC guidelines (2020) call them unrestricted, semi-restricted, restricted and disposal. Changing rooms and reception are in the outer zone, pre-operating and recovery rooms in the clean zone, operating rooms and scrub in the aseptic zone, and the dirty utility and disposal corridor in the disposal zone.

Which way should air flow in an operating suite?

From cleaner rooms to less clean ones: from the theatre and preparation room out toward the corridors, and into the dirty utility. HTM 03-01 gives the open-door airflow for each pair of rooms.

What pressure should an operating theatre have?

It depends on the national standard. UK HTM 03-01 standard layout 1 gives 25 Pa for the theatre and 35 Pa for the lay-up preparation room; India's NABH guidance asks for at least 2.5 Pa; ASHRAE 170 asks for positive pressure without a figure.

Is the preparation room cleaner than the theatre?

In UK standard layout 1 it runs at a higher pressure (35 Pa against 25 Pa), so air flows from the preparation room into the theatre and protects the sterile instruments.

What is the difference between an operating theatre and an operating room?

None in function. "Operating theatre" is the UK term and "operating room" the US term. The suite or department is the theatre plus its support rooms.

What are the layout zones of an operation theatre?

An operation theatre suite is laid out in four zones by room cleanliness, as UK HTM 03-01 names them: sterile, clean, transitional and dirty. The suite steps from the lay-up preparation room and the theatre, through scrub, anaesthetic and corridor areas, out to the dirty utility and disposal route. Pressure and airflow step down in that order, and the routes for staff, patients, clean supplies and waste follow it.

What is the operating zone in an operating theatre?

The area around the operating table, which some codes hold to a cleaner class than the rest of the room. China's GB 50333-2013 gives a Class I room class 5 at the operating zone and class 6 around it. For ultra-clean ventilation, HTM 03-01 asks for a clean zone of at least 2.8 × 2.8 m under the canopy, marked by a contrasting inlay in the floor covering.

Related guides

Sources

Project enquiry

Send what you have

A room list, a floor plan or only the floor area is enough to start. After you submit, send drawings by email or WhatsApp.

We reply by email within one working day. We can sign an NDA before you send drawings.

WhatsApp +44 7962 561184 is our UK number for export enquiries. The factory is in Tianjin, China.

Fastest reply: message us on WhatsApp. Or use the form, and add your WhatsApp number so we can reply there.

Email: [email protected]
WhatsApp: +44 7962 561184

Step 1 of 2

Chat on WhatsAppGet a budget range